Search Catalog

Most Dk-Lok male connectors can be bored-through thermocouple fittings except those fittings with small male thread like 1/8 in.
To order, insert T in DMC male connector part number. Example: DMCT8-8N-S
Unit of Measure

Specifications

Z Series Ferrule

No

Material

Carbon Steel

Moly Coating

None

Dimensions

D - Tube O.D.

1 in25.4 mm

Thread Type

PF

T - Thread Size

1/2

E - Min.

11.9 mm

h - Width Across Flat

1-3/8 in34.9 mm

H - Width Across Flat

1-1/2 in38.1 mm

A

31.2 mm

B

26.4 mm

l

43.7 mm

l1

14.2 mm

L

55.9 mm

K

25.9 mm